11kV three phase transformer

2023-10-08 16:56:24

Product Description:

power grid transmission and distribution station, industry & commerce electrical substation as the electrical equipment of power transmission


star and:

GB1094.1-2013;GB1094.2-2013;GB1094.3-2013;GB1094.5-2008;GB/T6451-2008;GB/T 1094.10-2003;JB/T 10088-2004 IEC60076;SABS 780 STANDARDS


Features of Products:

1.Ratedvoltage:6.3kV,10kV,11kV,13.2kV,13.8kV,15kV,20KV,22KV,33KV,35KV

2.2.Rated power: 5kva-25000kva

3,Two windings or three windings

4,On-load or no-load voltage tapping changer

5.Frequency:50HZ/60Hz

6.Vector group: Dyn11,Yyn0, Ynd11, or others

7.Cooling: ONAN/ ONAF/ OFAF

8.Tap changer:3 levels; 5 levels; 7 levels; 13 levels; 17 levels


Service Condition

1.Suitable for indoor or outdoor application

2.Air temperature: Maximum temperature: +-40°C; Minimum temperature:-30°C

a.Humidity: Monthly average humidity 9596; Daily average humidity 90%6 .

b.Altitude above sea level: Maximum installation altitude: 2000m.

3.Max wind speed:35M/s

a.Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.

b.No frequent violent shake.


Three phase oil immersed distribution transformer

view detail
01

KBSG mine flameproof dry-type transformer

2023-10-08 15:58:50

Features of Products

The KBSG series mininq explosion isolation dry transforrner conforrns to new GB 8286, mineral product separates explode migration

transformer substation requests. lnsulating the materal adopts C class or H class to insulate, hot stablity good, cooling offiway a doption ANAN,be applicble to there are air and coaldust of the methane mixture, and there is the mineral well, mineral mountain,tunnel of explosion dangeretc. environment.also be applicable to shortage with air and steam environment which decays metals and breakage to insulate. Settle thefrequency as 50 Hz.aprimary voltage is 6 ks or 10 k's, andneuterqender not to connect ground for the power system,for use various motiveequipments in the environment with various use electricity device to provide power supply.

Standard

JB3955-1993;GB1094.1~2-1996;GB12173-2008;GB1094.3-2003;GB1094.5-2008


Using environment and working condition

1.The elevation is less than 1000m, the special environment gives the explanation in addition

2.Ambient temperature: Highest temperature+40C;Lowest temperature-5'C; Maximum daily average temperature +30C; Maximum annualaverage temperature +20°C; Lowest outdoor air temperature-5C;

3.The relative humidity is less than 95%(When the air temperature is 25℃);

4.In has the methane and the coal dust, also has the explosion hazard in the mine pit;

5.Does not have, the vibration as well as with the gradient does not surpass in 15 environment;

6.Does not have sufficiently the dipping and the insulation gas and the steam;

7.No-water drop place;

8.Power supply voltage profile is approximate to the sine wave;

9.The three-phase supply voltage approximate is symmetrical;(When extracts this condition stipulation, separate consultation)

view detail
01

33kV11kV dry-type transformer

2023-10-08 15:54:08

Features of Products

33kV class Dry-type transformers are widely used in locallighting, high-rise buildings, airports, wharf CNC machinery and other places.

Simply speaking, dry-type transformers refer to transformers in which iron cores and windings are notimmersed in insulating

oil.

Cooling methods are divided into natural air cooling (AN) and forced air cooling(AF). During natural air cooling.

the transformer can operate continuously for a long time at rated capacity. When forced air cooling occurs, the output capacity of the transformer can be increased by 50%.

Suitable for intermittent overload operation or emergency overload operation; Since the load loss and impedance voltage increase greatly during overload and are in non-economic operation.

it should not be kept in continuous overload operation for a long time.


Standard

Full complied with GB/T 10228-2008; GB 1094.11-2007, IEC60076 STANDARDS

SCB10 SERIES 33kV CLASS DRY TYPE TRANSFORMER

view detail
01

11kv class dry type transformer

2023-10-08 15:38:41

Features of Products

Dry-type transformers are widely used in local lighting, high-rise buildings, airports, wharf CNc machinery and other places.Simply speaking, dry-type transformers refer to transformers in which iron cores and windings are not immersed in insulating oi.Cooling methods are divided into natural air cooling(AN) and forced air cooling (AF).During natural air cooling.

the transformer can operate continuously for a long time at rated capacty. When forced air cooling occurs,the output capacity of thetransformer can be increased by 50%.

Suitable for intermittent overload operation or emergency overload operation; Since the load loss and impedance voltage increase greatly duringoverload and are in non-economic operation,

it should not be kept in continuous overload operation for a long time.

Sc(B)10 Series 11kv Class Dry Type Transformer Technical Data

view detail
01

ZT(P)S series phase-shifting rectifier transformer

2023-10-08 15:35:59

Product Description

The converter transformer for variable frequency speed regulation is the power supply part of the high-voltage frequency converter. It plays the role of isolation, phase shifting and multiplexing. It is one of the core components of the high-voltage frequency converter. According to the cooling method, it is divided into dry type and oil-immersed type. kind.


The insulation grade of the dry-type converter transformer for variable frequency speed regulation produced by our company is Class H. The new insulation structure and advanced technology are used in the structural and electrical design to improve the short-circuit resistance and electrical strength, making the performance more reliable. During the design process, the impact of harmonics generated by rectifier components on the transformer windings and core is fully considered. Sufficient margin is provided to enable the windings and core to withstand the additional temperature rise caused by harmonics and maintain low noise, ensuring the reliability of the transformer. service life.


The winding temperature rise caused by harmonics is fully considered during design and manufacturing, which effectively ensures the service life of the transformer; VPI (vacuum pressure) impregnated paint and cured at high temperature have good moisture-proof, dust-proof, and anti-pollution effects, ensuring the reliability of the transformer. .


The materials selected undergo strict quality inspection, and all raw material manufacturers are strictly reviewed in accordance with ISO9001. The product has the characteristics of high reliability and is widely used with 6-pulse, 12-pulse, 18-pulse and multi-pulse frequency converters. According to the types of inverters and rectifiers and user requirements, special design and manufacturing plans are formulated.


Model Meaning

view detail
01

ZSCB double split rectifier transformer

2023-10-08 15:26:43

ZSCB double-split epoxy resin cast rectifier transformer is a new high-tech dry-type rectifier transformer developed by our company. It is produced using high-quality materials and advanced production and testing equipment according to strict processes.

view detail
01

SC13/SC11 series special dry-type transformer for central cabinet

2023-10-08 15:02:11

The three-phase dry type amorphous alloy core distribution transformer is a high-performance and energy-efficient power distribution solution. With its amorphous alloy core, this transformer offers reduced magnetic losses and improved efficiency, resulting in lower energy consumption. It is designed for applications where safety, reliability, and environmental concerns are paramount. This transformer is suitable for use in various industries, including manufacturing, commercial buildings, and infrastructure. It is easy to install and maintain, making it an ideal choice for modern power distribution systems.

view detail
01

SC(ZB) series dry type transformer

2023-10-08 14:53:14

Resin insulated dry-type transformers are safe, flame retardant, non-polluting and can be installed directly in load centers.

view detail
01

DKDC grounding transformer

2023-10-08 14:32:02

Grounding transformers are often used to provide an artificial loadable neutral point for system grounding at ungrounded points in the system. The neutral point of this product is connected to the arc suppression coil or resistor, and then grounded. It can be equipped with a secondary winding of continuous rated capacity as the power supply for the station (station).

view detail
01

Three-phase dry type amorphous alloy core distribution transform

2023-09-16 14:07:19

The three-phase dry type amorphous alloy core distribution transformer is a high-performance and energy-efficient power distribution solution. With its amorphous alloy core, this transformer offers reduced magnetic losses and improved efficiency, resulting in lower energy consumption. It is designed for applications where safety, reliability, and environmental concerns are paramount. This transformer is suitable for use in various industries, including manufacturing, commercial buildings, and infrastructure. It is easy to install and maintain, making it an ideal choice for modern power distribution systems.